RS-232 Controller

Connection

Use a “null-modem” 9-pin RS-232 cable to connect a PC or home theater control/automation
system (if present) to the RS-232/485 port on the Vision 110; see Figure 3-15.

For more information about using this connection, refer to Serial Communications on
page 63
.

Figure 3-15. RS-232 Control System Connection

WIRED REMOTE

WIRED REMOTE

Service port.

Not for user

access

to Automation/

Control System

or PC

1

2

3

4

5

7

8

9

6

5 Ground
3 Transmit Data
2 Receive Data

(none of the other pins are used)