Homepage layout configuration url – Vivotek IP3111/IP3121 User Manual
Page 84

www.vivotek.com
T:
886-2-22404099
F:
886-2-22404097
83
inter
<integer>
seconds delay to capture post-event
dihigh
< not required >
set DI high as trigger condition
dilow
< not required >
set DI low as trigger condition
dirise
< not required >
set DI rising as trigger condition
difall
< not required >
set DI falling as trigger condition
motion1
< not required >
set motion window1 as trigger condition
motion2
< not required >
set motion window2 as trigger condition
motion3
< not required >
set motion window3 as trigger condition
ioalarm
< not required >
trigger DO when DI condition matched
mdalarm
< not required >
trigger DO when motion detected
ioupload
< not required >
upload snapshot when DI condition matched
mdupload < not required >
upload snapshot when motion detected
sinter
<integer>
seconds interval for sequential mode
sbegin
<hh:mm:ss>
time to start sequential mode
send
<hh:mm:ss>
time to stop sequential mode
Homepage layout configuration URL
URL: /setup/layout.cgi
NAME VALUE
DESCRIPTION
blank hide
logo
def
use default logo
cuslogo
url
use image from URL
logourl
<text string shorter than 80 characters> URL of image for logo
linkurl
<text string shorter than 80 characters> URL to link when clicking on logo
blank
hide background image
def
use default background
cusback
url
use image from URL
backurl
<text string shorter than 80 characters> URL of image for background
fcolor
<0 ~ 15>
color index for font
bcolor
<0 ~ 15>
color index for background