Cleaning and maintenance, Trouble- shooting, Warning – Vanguard Heating Gas Log Heater User Manual

Page 25: Caution

Advertising
background image

25

103515

CLEANING

AND

MAINTENANCE

WARNING ICON

G 001

WARNING

Turn off heater and let cool before cleaning.

WARNING ICON

G 001

CAUTION

You must keep control areas, burner, and circulating air passage-
ways of heater clean. Inspect these areas of heater before each
use. Have heater inspected yearly by a qualified service person.
Heater may need more frequent cleaning due to excessive lint from
carpeting, bedding material, etc.

TROUBLE-

SHOOTING

Note: All troubleshooting

items are listed in order of

operation.

WARNING ICON

G 001

WARNING

Turn off and unplug heater and let cool before servicing. Only a
qualified service person should service and repair heater.

WARNING ICON

G 001

CAUTION

Never use a wire, needle, or similar object to clean ODS/pilot. This
can damage ODS/pilot unit.

POSSIBLE
CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or

wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode posi-

tioned wrong

7. Ignitor electrode broken

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if

pinched by any metal or
tubing. Keep ignitor
cable dry

3. Tighten nut holding

piezo ignitor to base
panel of log set. Nut is
located behind base
panel.

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace ignitor

7. Replace ignitor

OBSERVED
PROBLEM

When ignitor button
is pressed, there is no
spark at ODS/pilot

ODS/PILOT AND BURNER

• Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

• If you remove logs for cleaning, refer to Installing Logs, pages 20 and 21, to

properly replace logs.

• Replace log(s) if broken or chipped (dime-sized or larger).

Advertising