WATER SUPPLY REQUIREMENTS

E

ELLE

EC

CT

TR

RIIC

CA

ALL S

SH

HO

OC

CK

K H

HA

AZ

ZA

AR

RD

D

S

So

om

me

e w

waatte

err m

maayy rre

em

maaiin

n iin

n lliin

ne

e.. E

Elle

eccttrriicc

d

drriillll m

mu

usstt b

be

e g

grro

ou

un

nd

de

ed

d tto

o p

prre

evve

en

ntt sse

evve

erre

e o

orr

lle

etth

haall ssh

ho

occkk iiff w

waatte

err iiss iin

n lliin

ne

e aan

nd

d e

en

ntte

errss d

drriillll

d

du

urriin

ng

g u

usse

e..

U

Usse

e o

on

nllyy 1

1//4

4”” ((6

6 m

mm

m)) cco

op

pp

pe

err ttu

ub

biin

ng

g ffo

orr w

waatte

err lliin

ne

e.. D

Do

o

N

No

ott iin

nssttaallll cco

op

pp

pe

err ttu

ub

biin

ng

g iin

n aarre

eaa w

wh

he

erre

e tte

em

mp

pe

erraattu

urre

ess

d

drro

op

p b

be

ello

ow

w 3

35

5

o

o

F

F ((1

1..7

7

o

o

C

C)).. B

Be

effo

orre

e aattttaacch

hiin

ng

g cco

op

pp

pe

err ttu

ub

biin

ng

g

tto

o rre

effrriig

ge

erraatto

orr,, ffllu

ussh

h aatt lle

eaasstt 2

2 q

qu

uaarrttss ((1

1..9

9 LL)) o

off w

waatte

err

tth

hrro

ou

ug

gh

h tth

he

e cco

op

pp

pe

err ttu

ub

biin

ng

g aan

nd

d iin

ntto

o aa b

bu

ucckke

ett tto

o g

ge

ett rriid

d o

off

aan

nyy p

paarrttiicclle

ess iin

n tth

he

e w

waatte

err lliin

ne

e..

•Connect 1/4” (6mm) flexible copper tubing to household plumbing in compliance with local codes and ordinances.
•Length of copper tubing must reach from water supply connection to refrigerator connection plus an additional length

to facilitate moving the refrigerator out of enclosure for cleaning or service. Tubing should be soft instead of rigid and
ends should be free of burrs.

•Copper tubing route must be above 35oF (1.6oC) to prevent water line from freezing.
•If saddle valve is not used, place a separate shut-off valve in an easily accessible location between water supply and

refrigerator. Do not locate shut-off valve behind refrigerators.

••D

Do

o n

no

ott u

usse

e p

pllaassttiicc w

waatte

err lliin

ne

ess..

•D

Do

o n

no

ott u

usse

e sse

ellff--p

piie

errcciin

ng

g vvaallvve

e.. Viking Range Corporation is not responsible for property damage due to improper

installation or water connection.

•D

Do

o n

no

ott u

usse

e w

wiitth

h rre

evve

errsse

e o

ossm

mo

ossiiss w

waatte

err ffiillttrraattiio

on

n ssyysstte

em

m.. T

Th

hiiss w

wiillll vvo

oiid

d w

waarrrraan

nttyy

•Connect a vertical or horizontal 1/2” (1.2 cm) to 1 1/4” (3.2 cm) COLD water line near refrigerator area.
•Run water line through the floor, back or side wall. Tubing should lay flat on floor underneath refrigerator. Clamp

tubing to wall or floor.

•Water pressure must be greater than 20 psi and less than 120 psi.

To rough in water line:
1. Turn OFF main water supply. Turn ON nearest faucet long enough to clear line of water.
2. Vertical cold water line: Use grounded electric drill or hand drill to drill 3/16” (4.5 mm) hole in an easily accessible

location in water line.

Horizontal cold water line: Use grounded electric drill or hand drill to drill 3/16”
(4.5 mm) hole in the TOP of the water line. This will keep sediment from
collecting in valve.

3. Position washer over hole in water line. Place both halves of saddle valve bracket

against water line. turn saddle valve handle clockwise until firmly seated. The
saddle valve is now in the closed position. Tighten packing nut. Evenly and
firmly tighten bracket screws so washer will make a water-tight connection. Do
not overtighten screws: copper tubing could be crushed.

4. Check that both ends of copper tubing are cut square. Slide compression nut

and sleeve onto copper tubing. Insert end of copper tubing completely into
valve outlet. Tighten compression nut to outlet with adjustable wrench. Do not
overtighten.

Plumbing Dimensions