Connector pipe installation – Vogelzang International PB65XL User Manual

Page 6

Advertising
background image

Page 6

/ PB65XL

Vogelzang International Corp.

VGZ-003 / 20120327.0

CONNECTOR PIPE INSTALLATION

1. The smooth end of the stovepipe fits over the

cast iron flue collar at top rear of stove (fig. 5).

a). Crimped end of pipe must be away from

stove.

b). Hand form lower end (fig. 6) of stove pipe

to oval shape (fig. 7) and slide over flue outlet

collar as shown in figure 5.

c). Secure stove pipe to flue collar with

at least three (3) sheet metal screws and seal

with stove cement.

2. Horizontal pipe runs must slope upwards

towards the chimney at least 1/4” per foot of

horizontal run.

3. You must have at least 18 inches of clearance

between any horizontal piping and the ceiling.

4. The pipe cannot extend into the chimney flue

(figure 8).

5. Secure pipe/elbow sections with three (3)

sheet metal screws at each joint to make the

piping rigid.

Screws may be no more than a maxi-

mum of 3˝/76mm apart.

6. It is recommended that no more than two (2)

90 degree bends be used in the stovepipe in-

stallation. The use of more than two 90 degree

bends may decrease the amount of draw and

possibly cause smoke spillage. Where pos-

sible, use only corrugated (nonadjustable)

elbows. These provide a better seal.

7. The connector pipe must not pass through

an attic or roof space, trusses, closet, or any

concealed space, or floor, ceiling, wall or com-

bustible construction. (See Chimney Connector

NOTE: CONNECTOR PIPE IS NOT INCLUDED.
TO PURCHASE PIPE, VISIT YOUR LOCAL
HARDWARE, HOME OR BUILDING CEN-
TER. SEE “LOCATING STOVE” PAGE 4 FOR
ADDITIONAL SPECIFICATIONS.

CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FROM THE
STOVE.

Fig. 5 – Flue Outlet Collar

Fig. 6 – Hand-form pipe to oval shape – Fig. 7

CORRECT WRONG WRONG

Fig. 8 – Stovepipe/Flue Connections

Systems & clearances, page 10.) A UL 103 HT

Listed chimney system

must be used from the

first penetration of ceiling or wall to the chimney

cap. Use chimney components from a single

manufacturer. Do not mix brands.

WARNING: DO NOT USE SINGLE WALL CON-
NECTOR PIPE AS A CHIMNEY - A HOUSE FIRE
COULD RESULT.

Advertising