Owner’s manual, Installation – Vanguard Heating VSGF28PTC User Manual

Page 11

Advertising
background image

11

107156

OWNER’S MANUAL

For more information, visit www.desatech.com

Installation Items Needed

• 5/16" hex socket wrench or nut-driver

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not

provided)

1.

Remove fireplace screen. Remove two
screws that hold fireplace screen in
place for shipping. These screws are
located near top of screen. Discard
screws. Lift fireplace screen up and pull
out to remove.

2.

Remove screws that attach log base
assembly to fireplace (see Figure 19).
Carefully lift up log base assembly and
remove from fireplace (see Figure 19).

Note:

If adding the G8000 series brick liner

accessory, install it now. Follow instruc-
tions in G8000 accessory kit.

CONNECTING FIREPLACE
TO GAS SUPPLY

CAUTION: Do not pick up log

base assembly by burners. This
could damage burners. Only
handle base by grates.

3.

Route gas line (provided by installer)
from equipment shutoff through one of
the access holes.

Continued

Figure 19 - Removing Log Base Assembly
From Fireplace

Figure 20 - Attaching Flexible Gas Lines
Together

4.

Attach flexible gas line to gas supply
(see Figure 20). Check connection of
flexible gas line attached to gas regu-
lator of fireplace (see Figure 20).

5.

Check all gas connections for leaks. See
Checking Gas Connections, page 12.

6.

Replace log base assembly back into
fireplace. Feed flexible gas line into fire-
place base area while replacing log base
assembly. Make sure the entire flexible
gas line is in fireplace base area. Reat-
tach log base assembly to fireplace with
screws removed in step 2.

To Fireplace
Gas Regulator

Flexible Gas Line
from Equipment
Shutoff Valve

Equipment
Shutoff Valve
Provided by
Installer

To External
Regulator

NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
from the fireplace (see Figure 20).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.

INSTALLATION

Continued

Figure 18 - Gas Connection

* Purchase the optional CSA design-certi-
fied equipment shutoff valve from your
dealer. See Accessories, pages 22 and 23.

Installation must include an equipment
shutoff valve, union, and plugged 1/8" NPT
tap. Locate NPT tap within reach for test
gauge hook up. NPT tap must be upstream
from fireplace (see Figure 17, page 10).

IMPORTANT:

Install equipment shutoff

valve in an accessible location. The equip-
ment shutoff valve is for turning on or
shutting off the gas to the appliance.

Check your building codes for any special
requirements for locating equipment shutoff
valve to fireplaces.

Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.

CAUTION: Use pipe joint seal-

ant that is resistant to liquid pe-
troleum (LP) gas.

We recommend that you install a sediment
trap in supply line as shown in Figure 18.
Locate sediment trap where it is within
reach for cleaning. Install in piping system
between fuel supply and fireplace. Locate
sediment trap where trapped matter is not
likely to freeze. A sediment trap traps mois-
ture and contaminants. This keeps them
from going into fireplace gas controls. If
sediment trap is not installed or is installed
wrong, fireplace may not run properly.

CSA Design-
Certified Equipment
Shutoff Valve With
1/8" NPT Tap*

3" Minimum

Cap Pipe Tee

Nipple Joint

Sediment Trap

Advertising
This manual is related to the following products: