Owner’s manual, Troubleshooting, Continued – Vanguard Heating VSGF28PTC User Manual

Page 21

Advertising
background image

21

107156

OWNER’S MANUAL

For more information, visit www.desatech.com

TROUBLESHOOTING

Continued

WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating fireplace where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These odors
will disappear over time.

POSSIBLE CAUSE

1. Metal expanding while heating or con-

tracting while cooling

1. Fireplace burning vapors from paint, hair

spray, glues, cleaners, chemicals, new
carpet, etc. (See

IMPORTANT

state-

ment above)

2. Gas leak.

See Warning statement

above

1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged

1. Gas leak.

See Warning statement

above

2. Control valve defective

1. Foreign matter between control valve

and burner

2. Gas leak.

See Warning statement

above

1. Not enough combustion/ventilation air

OBSERVED PROBLEM

Fireplace produces a clicking/ticking noise
just after burners are lit or shut off

Fireplace produces unwanted odors

Fireplace shuts off in use (ODS operates)

Gas odor even when control knob is in OFF
position

Gas odor during combustion

Moisture/condensation noticed on windows

REMEDY

1. This is common with most fireplaces. If

noise is excessive, contact qualified ser-
vice person

1. Open window and ventilate room. Stop

using odor causing products while fire-
place is running

2. Locate and correct all leaks (see Check-

ing Gas Connections, page 12)

1. Open window and/or door for ventilation
2. Contact local propane/LP gas company
3. Clean ODS/pilot (see Cleaning and

Maintenance, page 18)

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 12)

2. Replace control valve

1. Take apart gas tubing and remove

foreign matter

2. Locate and correct all leaks (see Check-

ing Gas Connections, page 12)

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

www.desatech.com

Advertising
This manual is related to the following products: