Important safety information, Audible alarm reset switch installation, Warning placard installation – Viking Access Systems Vehicular Gate Opener X-9 User Manual

Page 10

Advertising
background image

TECHNICAL SUPPORT 1 800 908 0884

8

Audible Alarm Reset Switch Installation

WARNING - Not following these instructions may cause severe injury or death to persons.

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION

Warning Placard Installation

Manual Stop

Button

5'

Minimum

STOP

Radio Station

Mag.

Lock

M

a

g

.

Lo

ck

Safety Connector

Open Commands

Guard Station

Master/Slave

Brake

UL

Siren

Radio

Rec.

UL

Sensor

O

P

E

N

R

IG

H

T

2

4

V

B

A

T

2

4

V

A

C

O

P

E

N

L

E

FT

Safety

Loop

Center

Loop

Obstruction

Sensor

Charger

Power

Low Battery

Motor Sensor

Hold Open

Timer

Stop

Overlap Delay

Close

Open

O

b

st

ru

ct

io

n

S

e

n

so

r

min.

MAX

O

ve

rl

a

p

D

e

la

y

1.

5

0

3

Radio Station

Loop Connector

Open Commands

Guard Station

Master/Slave

G

N

D

C

lo

se

S

to

p

O

p

e

n

G

N

D

C

lo

se

S

to

p

O

p

e

n

G

n

d

Fi

re

G

n

d

S

tr

ik

e

G

n

d

Ex

it

G

n

d

C

e

n

te

r

G

n

d

Re

op

en

G

n

d

U

L

G

n

d

+

2

8

v

G

n

d

R

a

d

io

G

n

d

+

2

8

v

+

2

8

v

M

a

g

.

Lo

ck

Fail

Safe/Secure

M

A

G

.

LO

C

K

N.C.

COM

N.O.

Charger

Power

Low Battery

Motor Sensor

H

o

ld

O

p

e

n

Ti

m

e

r

S

to

p

C

lo

se

O

p

e

n

3

0

6

0

O

ff

1

R

a

d

io

R

e

c.

U

L

S

e

n

s

S

a

fe

ty

Lo

o

p

C

e

n

te

r

Lo

o

p

B

ra

ke

Si

re

n

COM

N.O.

ST

OP

Manual Reset for the Audible Alarm

UL325 standard requires an audible alarm to go off after two consecutive events
detected by the primary entrapment protection of the gate operator (obstruction sensor).

The audible alarm will continue to sound for 5 minutes or until a stop command
gets actuated.

The Stop command can be actuated in two different forms

1. Using the Built in Stop switch on the Control Box or

2. Using an External Stop button within the sight of the gate, away from moving

parts of the gate and out of reach of children.

3. Controls intended for user activation must be located at least six feet (6’) away

from any moving part of the gate and where the user is prevented from reaching
over, under, around or through the gate to operate the controls. Outdoor or easily
accessible controls shall have a security feature to prevent unauthorized use.

4. The Stop and/or Reset button must be located in the line-of-sight of the gate.

Activation of the reset control shall not cause the operator to start.

All Warning Signs and Placards must be installed where visible in the area
of the gate. A minimum of two placards shall be installed. A placard is
to be installed in the area of each side of the gate and be visible.