Important safety information – Viking Access Systems Vehicular Gate Opener X-9 User Manual

Page 9

Advertising
background image

TECHNICAL SUPPORT 1 800 908 0884

7

Radio Station

Mag.

Lock

M

a

g

.

Lo

ck

Safety Connector

Open Commands

Guard Station

Master/Slave

Brake

UL

Siren

Radio

Rec.

UL

Sensor

O

P

E

N

R

IG

H

T

2

4

V

B

A

T

2

4

V

A

C

O

P

E

N

L

E

FT

Safety

Loop

Center

Loop

Obstruction

Sensor

Charger

Power

Low Battery

Motor Sensor

Hold Open

Timer

Stop

Overlap Delay

Close

Open

O

b

st

ru

ct

io

n

S

e

n

so

r

min.

MAX

O

ve

rl

a

p

D

e

la

y

1.

5

0

3

Radio Station

Loop Connector

Open Commands

Guard Station

Master/Slave

G

N

D

C

lo

se

S

to

p

O

p

e

n

G

N

D

C

lo

se

S

to

p

O

p

e

n

G

n

d

Fi

re

G

n

d

S

tr

ik

e

G

n

d

Ex

it

G

n

d

C

e

n

te

r

G

n

d

Re

op

en

G

n

d

U

L

G

n

d

+

2

8

v

G

n

d

R

a

d

io

G

n

d

+

2

8

v

+

2

8

v

M

a

g

.

Lo

ck

Fail

Safe/Secure

M

A

G

.

LO

C

K

N.C.

COM

N.O.

Charger

Power

Low Battery

Motor Sensor

H

o

ld

O

p

e

n

Ti

m

e

r

S

to

p

C

lo

se

O

p

e

n

3

0

6

0

O

ff

1

R

a

d

io

R

e

c.

U

L

S

e

n

s

S

a

fe

ty

Lo

o

p

C

e

n

te

r

Lo

o

p

B

ra

ke

Si

re

n

WARNING - Not following these instructions may cause severe injury or death to persons.

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION

Edge Sensor (contact sensor) Installation

Manual Release

When manual operation is required:
Remove the cover, locate the chained key and
turn the key to push the locking-pin down.

At end of operations, lock the geared motor again
by releasing locking-pin.

Attention: Lock and release operations MUST
be performed with motor NOT RUNNING.

3-Sided Edge Sensor

3-Sided Edge Sensor

Edge sensor or like must be installed to reduce the risk of entrapment.

Use only Miller Edge 3-sided activation type MGR20 or MDS20 to comply with UL325

One or more contact sensors shall be located on the inside and outside leading edge
of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6
inches (152 mm) above the ground at any point in its arc of travel, one or more
contact sensors shall be located on the bottom edge.

1. A hardwired contact sensor shall be located and its wiring arranged so that the

communication between the sensor and the gate operator is not subjected to
mechanical damage.

2. A wireless contact sensor such as one that transmits radio frequency (RF) signals

to the gate operator for entrapment protection functions shall be located where
the transmission of the signals are not obstructed or impeded by building
structures, natural landscaping or similar obstruction. A wireless contact sensor
shall function under the intended end-use conditions.

Advertising