Gate operator installation, Limit switch setup – Viking Access Systems Vehicular Gate Opener X-9 User Manual

Page 16

Advertising
background image

TECHNICAL SUPPORT 1 800 908 0884

14

18

STEP 8

A. Loosen the screws on the limit switch

cams and position the cams to the desired
locations. There are additional holes
provided in case of a wide or tight angle
of opening or closing.

B. Move the gate manually and ensure that

the limit switch gets actuated at the
desired open and closed position. The
limit switch will click when engaged by
the limit cam.

C. Retighten the screws on the limit switch

holders once the proper position has been
determined.
CAUTION – DO NOT OVERTIGHTEN
SCREWS!

D. Run the unit 2 full cycles without

interruption (from limit to limit) to
execute a “Learn Cycle.”

E. Fine-tune the adjustment of the Limit

Switch Cams.

Position Cam

to Suit

Tighten Clamping
Screw Securely
Before Adjusting
Cams

Limit Switch

Holder

Additional Cam
Mounting Holes

Note: Leave cover off until after the installation
of the control box and the electrical
installation. Verify that the operator opens
and closes to the desired position under
power. Make any adjustments as necessary.

STEP 9

Replace the cover and secure it with screws
provided after finishing final adjustments.

Limit Switch Setup

GATE OPERATOR INSTALLATION

GATE OPERATOR INSTALLATION

Advertising