DESCRIPTION

The 50M56U-843 kit is a Universal Single Stage HSI Integrated
Furnace Control that employs a microprocessor to continually
monitor, analyze, and control the proper operation of the gas
burner, inducer, and fan.

The kit contains:
• 50M56-843 Ignition Control Module
• 21D64-2 Ignitor Kit
• Set of Interconnect Harnesses

Installation should be done by a qualified heating and air
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.
Following installation or replacement, follow manufacturer’s
recommended installation/service instructions to ensure
proper operation.

PRECAUTIONS

PART NO. 37-7042B

Replaces 37-7042A

0937

Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage the
thermostat.

CAUTION

!

Failure to comply with the following warnings could result
in personal injury or property damage.

FIRE HAZARD

• Do not exceed the specified voltage.
• Replace existing control with exact model and

dash number.

• Protect the control from direct contact with water

(dripping, spraying, rain, etc.).

• If the control has been in direct contact with

water, replace the control.

• Label all wires before disconnection when serv-

icing controls. Wiring errors can cause improper
and dangerous operation.

• Route and secure wiring away from flame.

SHOCK HAZARD

• Disconnect electric power before servicing.
• Ensure proper earth grounding of appliance.
• Ensure proper connection of line neutral and line

hot wires.

EXPLOSION HAZARD

• Shut off main gas to appliance until installation

is complete.

WARNING

!

THE SUPPLIED WIRING HARNESSES ALLOW
THE “UNIVERSAL 50M56U-843” TO BE USED
IN NUMEROUS APPLICATIONS. FOR PROPER
INSTALLATION THE INSTALLER MUST READ
“PAGE 2 AND 3” MOUNTING AND WIRING.

INSTALLER MUST READ

CONTENTS

Description ................................................................... 1
Precautions .................................................................. 1
Specifications .............................................................. 2
Installation ................................................................... 2
Mounting & Wiring
Operation ..................................................................... 7

50M56-843

21D64-2

Advertising