Gas conversion, Warning, L.p. gas conversion – Whirlpool Freestanding Gas Range User Manual

Page 8

Advertising
background image

6.

Oven burner:

a.

Open oven door and remove oven

racks, oven tray, flame spreader and set
aside. Lift oven burner. The orifice spud is
behind the oven burner air shutter.

b.

Locate L.P. gas orifice spud stamped

“56” in literature package supplied with
range.

c.

Use a 3/8" combination wrench and

remove the natural gas orifice spud.
Install the number “56” L.P. gas spud.

Place natural gas oven burner spud in
plastic parts bag along with natural gas
cooktop burner spuds for future use and
keep with literature package.

d.

Reinstall the oven burner.

7.

Turn manual shutoff valve in gas

supply line on. If “Gas and electrical
connection” Steps 10–16 on Page 6 were
not completed, complete them now.

8.

Install control knobs. Check for

proper flame. The cooktop burner flames
should have a small inner cone with a
very distinct blue flame 1/4" (6.4 mm) to
1/2" (1.3 cm) long. The outer cone is not
as distinct as the inner cone. The oven
burner flame should be 1/2" (1.3 cm) long
with a bluish-green inner cone and dark
blue outer mantle. L.P. gas flames have a
slightly yellow tip. If the flames are noisy
or blowing, they are getting too much air.
If the flames are soft and lazy, they are
not getting enough air. If burners need
adjusting, see “Check operation” section,
Steps 17–22, Page 7.

8

Gas conversion

Gas conversions (from Natural gas to L.P.
gas; or from L.P. gas to Natural gas) must
be done by a qualified installer.

L.P. gas conversion

1.

Complete installation Steps 1–9

(Pages 5-6) before converting cooktop to
L.P. gas. Check that the manual shutoff
valve in the gas supply line has been
turned off.

2.

Open broiler drawer and remove

broiler pan. The pressure regulator is
located in the back right hand corner of
the broiler compartment.

4.

Remove burner grates, burner caps,

burners and screws. Lift cooktop.

NOTE: There is no cooktop support rod.

5.

Cooktop burners:

a.

Check that all control knobs are in the

OFF position and remove the knobs.

b.

Remove the control panel. (See Step

17a, Page 7.)

c.

Lift front of bracket and push tube and

bracket assembly back off orifice.

Do not remove the pressure regulator.

3.

Pressure

regulator: Remove
the cap from the
pressure regulator.
Turn the cap over so
that LP is visible.
Replace the cap.

burner

burner cap

screw

viewed from
inside broiler
compartment

d.

Locate L.P. gas orifice spuds for top

burners in literature package included
with the range. Three L.P. gas spuds are
stamped “65” and one “62”. Remove
Natural gas orifice spuds using a 3/8"
combination wrench. Install L.P. gas
orifice spuds in locations shown to
replace the Natural gas orifice spuds.

NOTE: Depending on model, the range
cooktop may be equipped with 4
standard burners or 3 standard burners
and 1 power burner. Spud size/location
remain the same.

orifice spuds

NAT

L.P.

L.R.

L.F.

R.R.

R.F.

gas

manifold

notches

Remove and replace
orifice spuds.

NOTE: Burner tube and
brackets not shown.

“65”

“62”

“65”

“65”

Place Natural gas orifice spuds in plastic
parts bag for future use and keep with
literature package.

Reinstall burner tube and bracket
assemblies.

e.

Lower cooktop. Reinstall screws to

secure burner tubes to cooktop. Reinstall
burners, burner caps and burner grates.

Do not reinstall control panel or knobs.
They will be reinstalled in Step 10, Page 9.

oven burner
orifice behind
air shutter

L.P. oven orifice
spud stamped
with “56”

burner
tube

bracket

orifice

Fire Hazard

Shut off gas supply line valve.

Make all conversions before turning
gas supply valve back on.

Failure to follow these instructions can
result in explosion, fire or injury.

WARNING

Advertising