MAINTENANCE

Regular maintenance is essential in keeping your WINDSOR Elevator in
proper operating condition. Please remember you, as the owner of this
equipment, are responsible for making sure maintenance and upkeep is
performed on a regularly scheduled basis.

We strongly urge you to protect your investment by having only an
authorized Access Industries' dealer perform all required maintenance,
service and repair work. They are trained technicians, qualified to do the
job.

To assure proper operating condition of your elevator, the items listed
below should be inspected and/or serviced every six (6) months.

Tighten all track and car hardware.

Inspect drive cables wear. Cables must be replaced if showing signs

of wear.

Inspect drive unit drums for wear and tightness to shafts. Drum must

be replaced if showing signs of wear.

Verify proper operation of unit control switches.

Verify proper operation of both landing controls.

Inspect trailing cable for wear or damage. Cable must be replaced if

wear, cuts or damage is evident.

Inspect vent plug to insure it is clean and operating.

Inspect limit switches, door switches and cams for wear or damage.

Switches and/or cams must be replaced if wear or damage is
evident.