Notice, Installation, Caution – Wayne Jet Pump JSU50 User Manual

Page 3: Warning

Advertising
background image

(A) MANANTIAL:

Un manantial que emerge

de la tierra. Ocurre cuando

el agua en materiales

permeables está atrapada

entre materiales

impermeables tales como

roca o arcilla.

(B) LAGO, ARROYO o EST

ANQUE:

Agua superficial, que a menos

que sea tratada, por lo general

no es apta para consumo

humano. Puede ser utilizada

para fines tales como lavado

o irrigación.

(C) POZO EXCA

V

ADO:

Se excava un hoyo de

varios pies de diámetro

hasta una profundidad

basante superficial.

Luego se reviste con

ladrillo, piedra o

concreto para evitar

que se derrumbe.

(D) POZO ACCIONADO:

Se acciona una tubería

con una pantalla con

punta en la tierra, por

debajo de la capa

freática. La profundidad

por lo general es menor

a 15,25 m (50 pies).

Los diámetros comunes

fluctúan entre 2,5 cm (1")

y 5,1 cm (2")

(E) POZO PERFORADO:

Un hoyo perforado en

la tierra con maquinaria y

revestido con tuberías.

Las profundidades

fluctúan entre algunos

pies hasta más de 305 m

(1000 pies). Los diámetros

comunes son 5,1 cm (2"),

7,6 cm (3"), 10,2 cm (4") y

15,2 cm (6") para pozos

de agua de uso doméstico.

(F) CISTERNA:

Un tanque subterráneo

construido para recolectar

agua de lluvias de los

techos. El agua no es

apta para consumo

humano.

(A) MANANTIAL

(B) LAGO,

ARROYO,

EST

ANQUE

(C) POZO EXCA

V

ADO

(D) POZO

ACCIONADO

(E) POZO

PERFORADO

(F) CISTERNA

MA

TERIAL

PERMEABLE

ARENA

ACUIFERA

CAP

A FREA

TICA

ESQUISTO

TIERRA

SUPERFICIAL

ARCILLA

Suministr

os de Agua

Figura 11 - Suministros de agua

Manual de Instrucciones de Operación y Piezas

JSU50

As an alternative, an in-line check valve
can be used with a driven well (Figure
9).

Do not use both a
check valve and

foot valve in your system. This could
significantly reduce the performance of
the pump.

DRILLED WELL

1. Install a foot valve on the first sec-

tion of pipe (Figure 10).

2. Lower the pipe into the well.

3. Add pipe until the foot valve is 10

feet below the lowest anticipated
water level.

Leaking joints or couplings will allow
air to leak into the pipe and cause poor
pump operation. Make sure to use pipe
joint compound or Teflon

®

tape on all

pipe connections.

Locate foot valve

at least 2 feet from

the bottom of the well so sand or sedi-
ment is not drawn into the system.

!

CAUTION

NOTICE

3

22 Sp

Installation

(Continued)

8. Slope horizontal lines up toward

pump a minimum of 1/4" per foot.
This will prevent trapping air in the
lines.

ELECTRICAL CONNECTIONS

The voltage of power supply must
match the voltage of the pump. Above
ground well pumps covered in this
manual have dual voltage motors pre-
set at the factory to 230 volts. The
motors can be converted to 115 volts by
turning the voltage selector to the
desired voltage (See Figure 6). Use a
needle nose pliers to pull the selector
out approximately 1/4”, rotate and
then reinsert in correct position.

Connect the pump to a separate electri-
cal circuit with a dedicated circuit
breaker. Refer to the electrical specifi-
cations in the Wiring Chart for recom-
mended circuit breaker and wire size.

Install and main–
tain wiring for this

pump in accordance with the National
Electrical Code and all applicable local
codes.

The motor must be grounded by con-
necting a copper conductor to the
grounding screw provided within the
wiring compartment in the pressure
switch.

The field wiring compartment for the
jet pump is inside the pressure switch
housing. There is only one proper
ground screw on the unit. The screw is
located under the pressure switch
cover, painted green and is identified
as GRD. The ground connection must
be made to this terminal (Figure 7).

!

WARNING

Refer to the wiring diagram located
under the cover of the pressure switch
(Figure 7).

To attach AC power to the switch,
loosen the screw holding the cover
onto the switch and remove the cover.

Loosen unused ground screw and
attach the exposed end of the ground
wire between the screw head and the
pressure switch body, then tighten.

Loosen the top two screws on the pres-
sure switch and retighten with the AC
power leads captured under the screw
heads. Reattach the pressure switch
cover and tighten the screw.

CONNECTION TO WATER SOURCE

DRIVEN WELL

1. Drive the point several feet below

the water table.

NOTE: A packer-type foot valve can be
installed in the well (Figure 8). This
type of foot valve allows the well pipe
to be filled with water when priming
and makes the inlet pipe much easier
to test for leaks. Follow the manufac-
turer’s instructions when installing the
packer-type foot valve.

L2

L2

3

L1

L1

1

Figure 7 - Electrical Connections

Attach
Ground
Wire
Here

Operating Instructions and Parts Manual

JSU50

Figure 8 - Packer-Type Foot Valve

To pump

Packer Type
Foot Valve

Drive
Point

Figure 9 - In-Line Check Valve

To
pump

Inline
check
valve

Drive
Point

Figure 10 - Well Seal

To
pump

Well seal

Foot valve

Well casing

www.waynepumps.com

Motor

Line

115 V

230 V

115 V

230 V

Figure 6 - Voltage Selector