White Rodgers 1F80-71 User Manual

White-rodgers, Description, Operator: save these instructions for future use

Advertising
background image

To prevent electrical shock and/or equipment damage
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

Printed in U.S.A.

DESCRIPTION

1F80-71

Programmable Electronic

Digital Automatic Changeover Single Stage Thermostat

INSTALLATION AND

OPERATION INSTRUCTIONS

PART NO. 37-6120A

9934

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Your new White-Rodgers 5-Day/2-Day Single Stage Digital
Thermostat uses the technology of a solid-state microcomputer
to provide precise time/temperature control. This thermostat
offers you the flexibility to design heating and cooling programs
that fit your needs.

Features:

• Separate 5-day (weekday) and 2-day (weekend) programming

with four separate time/temperature periods per program

• Simultaneous heat and cool program storage
• Automatic changeover
• Optional C terminal (dual power option)

PRECAUTIONS

SPECIFICATIONS

• Optional Energy Management Recovery (EMR)
• Optional B and O terminals
• Preprogrammed temperature control
• LCD continuously displays set point, and alternately dis-

plays time and room temperature

• Temperature override until next program period
• Manual program override (HOLD temperature)

°

F/

°

C convertibility

• Temperature range 45

°

to 90

°

F

• Keypad lockout
• Armchair programming capability

This thermostat is intended for use with a 24-volt system; do not
use this thermostat with a millivolt or line voltage system. If in
doubt about whether your wiring is millivolt, line, or low voltage,
have it inspected by a qualified heating and air conditioning
contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

ELECTRICAL DATA
Electrical Rating:

8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA
Setpoint Temperature Range:

45

°

F to 90

°

F (7

°

C to 32

°

C)

Operating Ambient Temperature Range:

32

°

F to 105

°

F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°

F to 150

°

F

APPLICATIONS

For use with:

Standard heat/cool or heat only systems

Electric heat systems

Gas or oil fired systems

Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers

Hydronic (hot water or steam) systems

DO NOT USE WITH:

Multi-stage systems

Systems exceeding 30 VAC and 1.5 amps

Millivolt systems

3-wire zoned hydronic heating systems

CAUTION

!

WARNING

!

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

WHITE-RODGERS