4. Fill sump with water. The pump will start

automatically when the water has filled
the sump to the cut-in level. The pump
will stop when the water reaches the
cut-out level. See specifications for cut-
in/out levels. The pump will recycle
thereafter as required.

5. Do not operate the pump unless it is

submerged in water. Dry running causes
pump failure.

6. The motor is equipped with an

automatic reset thermal protector.

7. While the pump is draining the pit, verify

that the discharge piping is carrying the
water to a point several feet away from
the foundation.

8. If pump discharge line is exposed to

freezing temperature, the exposed line
must be pitched to drain. Trapped water
will freeze and damage the pump.

Maintenance

Always disconnect the
electrical supply before
attempting to install,
service, relocate or
perform any maintenance. If the power
source is out of sight, lock and tag in
the open (off) position to prevent
unexpected power application. Failure
to do so could result in fatal electrical

Operation (Continued)

Risk of electrical
shock! This pump

is supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce
the risk of fatal electrical shock.
Never cut off the round grounding prong.
Cutting the cord or plug will void the
warranty and make the pump inoperable.

2. This pump is only for use on 120 Volt

(single-phase), 60 hz, 15 amp service and
is equipped with a 3-conductor cord and
3-prong, grounding type plug. Insert the
float switch cord plug directly into a 120
volt outlet.

3. Insert the pump power cord plug directly

into the back of the float switch cord
plug (See Fig. 3).

2

Operating Instructions and Parts Manual

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Pump will not start or
run

Pump starts and stops
too often

Pump will not shut off
or thermal protector
turns off

Pump operates but
delivers little or no
water

1. Blown fuse
2. Low line voltage
3. Defective motor
4. Defective float switch
5. Impeller bound-up
6. Float obstructed

1. Backflow of water from piping
2. Faulty float switch

1. Defective float switch
2. Obstacle in piping
3. Float obstructed

1. Low line voltage
2. Plugged impeller

1. If blown, replace with proper sized fuse or reset breaker
2. If voltage is under 108 volts, check wiring size
3. Replace pump
4. Replace float switch
5. If impeller will not turn, remove housing and remove blockage
6. Make sure float move freely up and down

1. Install or replace check valve (Wayne check valve kit #66005-WYN)
2. Replace float switch

1. Replace float switch
2. Remove pump and clean pump and piping
3. Make sure float move freely up and down

1. If voltage is under 108 volts, check wiring size
2. Clean out impeller

shock. Only qualified electricians
should repair this unit. Improper repair
could result in fatal electrical shock.
1. Let the pump cool for a minimum of two

hours before servicing because the
pump contains hot oil under pressure
and the motor is hot.

2. Disassembly of the motor prior to

expiration of warranty will void the
warranty. If repairs are required, see
troubleshooting chart.

4. Inlet should be kept clean and free of all

foreign objects and inspect annually. A
clogged inlet will damage pump.

5. Pump should be checked monthly for

proper operation.

This pump contains
dielectric oil for

cooling. This oil can be harmful to the
environment. Check the state
environmental laws before disposing
this oil.

Specifications

Power supply requirements.............120V, 60 hz
Motor ................................................Single phase, oil filled
Liquid temperature range ...............40°F to 120°F
Circuit requirements ........................15 amps (min)
Dimensions .......................................11” high x 9” base
Cut-in level (factory set) ..................Tether ...14” Float .....7”
Cut-out level (factory set)................Tether ...7”

Float .....2 1/2”

Construction

Motor housing .................................Glass reinforced thermoplastic
Volute ...............................................Thermoplastic
Impeller.............................................Glass reinforced thermoplastic
Shaft..................................................416 Stainless steel
Seals ..................................................Buna N
Discharge ..........................................1

1

/

2

” NPT

Figure 3

www.waynepumps.com