INSTALLER/CONFIGURATION MENU

CONFIGURATION MENU

Non-

Displayed

Press

or

7

Program-

Press

(Factory

to select from

Day

mable

Button

Default)

listed options

Comments

1

1

(GAS)

ELE

GAS setting: furnace controls blower.

ELE setting: thermostat controls blower.

2

2

Days (7)

5, 0

Selects programming option.

3

* NA

PS (4)

2

Selects programming periods per day.

4

3

Cool, Off,

Cool, Off, Heat,

Selects system switch configuration for heat and cool with

Heat, Auto

Off, Heat, Cool, Off

Auto changeover, Heat & Cool, Heat Only or Cool Only.

5

* NA

E (On)

OFF

Selects Energy Management Recovery on or off.

6

4

Cr Heat (FA)

SL

Selects Heat cycle rate Fast (FA) or Slow (SL).

7

5

Cr Cool (FA)

SL

Selects Cool cycle rate Fast (FA) or Slow (SL).

8

6

CL (OFF)

On

Selects Compressor lockout ON or OFF.

9

7

dL (On)

OFF

Selects display light on or off.

10

8

0

1, 2, 3, 4 HI

Selects temperature display adjustment 1, 2, 3 or 4 degrees

(Room temp)

1, 2, 3, 4 LO

high or low.

11

9

°F

°C

Selects Fahrenheit or Celsius temperature display.

12

10

b (On)

OFF

Selects beeper on or off.

13

11

Heat (99)

62-99

Selects highest Heat setpoint temperature.

Can select 62° to 99°F.

14

12

Cool (45)

45-82

Selects lowest Cool setpoint temperature.

Can select 45° to 82°F.

15

13

Keypad

L, P

Selects keypad lockout full or partial to be set.

lockout (L)

Temperature Limit

Activates temperature limit ranges.

16

14

Keypad

On

Selects keypad lockout on or off.

lockout (OFF)

000

000 to 999

Selects keypad lockout combination number if lockout is on.

000 is not a valid selection.

17

15

000 Change

On

Select change filter alert time period.

Filter (OFF)

200 hours

25 to 1975 hours

When set ON, selects time in 25 hour increments.

18

16

Change

On

Selects change humidifier pad alert time period

Humidifier

(OFF)

100 hours

25 to 1975 hours

When set ON, selects time in 25 hour increments.

To enter the menu: Press the

Menu button. Press and hold for 5 seconds the Installer Config button this displays menu item

#1 in the table below. Press

to advance to the next menu item or

to return to a previous menu item. Press

or

to

change a menu item.

1) GAS or Electric (ELE) fan operation. If the heating system

requires the thermostat to energize the fan, select ELE.
Select GAS if the heating system energizes the fan on a
call for heat. Note: Resetting the thermostat switches the
option to ELE.

2) This control can be configured for 7 independent day or

5/1/1 programming or non-programmable mode. The
display indicates "

7 Days" as default. The programs per

week can be toggled to "

5 Days" or "0 Days" by pressing

the

or

keys. A selection of 0 Days for non-program-

mable will eliminate the need for EMR, and that step
in the menu will be skipped.

3)

Programmable Periods – This control can be configured
for 4 or 2 programmable periods per day. The display
indicates "

4 PS" in the display as default. The program-

mable periods can be toggled by pressing the

or

keys.

4)

System Switch Configuration – This thermostat is
configured for Heat and Cool with Auto changeover
(SYSTEM switch with Cool Off Heat Auto) default. It can
also be configured for Heat and Cool (Cool Off Heat),
Heat only (Off Heat), and Cool only (Cool Off).

5)

Energy Management Recovery – (this step is skipped if
configured to be non-programmable).
Energy Management Recovery (E) On causes the
thermostat to start heating or cooling early to make the
building temperature reach the program setpoint at the
time you specify. Heating will start 5 minutes early for
every 1° of temperature required to reach setpoint.
Example: E On is selected and your heating is pro-
grammed to 65° at night and 70° at 7 AM. If the building
temperature is 65°, the difference between 65° and 70° is
5°. Allowing 5 minutes per degree, the thermostat set-
point will change to 70° at 6:35 AM. Cooling allows
more time per degree, because it takes longer to reach
temperature.

Menu

Reference

Number

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

* Not Applicable