Stop! read this before proceeding, User’s information manual – Weil-McLain ULTRA 550-100-067/0608 User Manual

Page 3

Advertising
background image

Part number 550-100-067/0608

3

gas

-

fired

water

boiler

— User’s Information Manual

Failure to adhere to the guidelines on this page can result in severe personal

injury, death or substantial property damage.

Boiler service and maintenance —

To avoid electric shock, disconnect electrical supply before performing mainte-

nance.

To avoid severe burns, allow boiler to cool before performing maintenance.

You must maintain the boiler as outlined in this manual and

have the boiler started

up and serviced at least annually

by a qualified service technician to ensure boiler/

system reliability.

Boiler operation —

Do not block flow of combustion or ventilation air to boiler. This boiler is equipped

with a control which will automatically shut down the boiler should air or vent be

blocked. If vent or air blockage is easily accessible and removable, remove it. The boiler

should attempt to restart. If blockage is not obvious or cannot be removed, have the

boiler and system checked by a qualified service technician.

Do not allow contaminated air to enter the boiler air inlet pipe. See page 4 for de-

tails.

Should overheating occur or gas supply fail to shut off, do not turn off or disconnect

electrical supply to boiler. Instead, shut off the gas supply at a location external to

the appliance.

Do not use this boiler if any part has been under water. Immediately call a qualified

service technician to inspect the boiler and to replace any part of the control system

and any gas control, which has been under water.

Boiler water —

Have boiler water chemistry checked at least annually by a qualified service techni-

cian.

DO NOT use petroleum-based cleaning or sealing compounds in boiler system. Gas-

kets and seals in the system may be damaged. This can result in substantial property

damage.

DO NOT use “homemade cures” or “boiler patent medicines”. Serious damage to

boiler, personnel and/or property may result.

Continual fresh makeup water will reduce boiler life. Mineral build-up in boiler heat

exchanger reduces heat transfer, overheats the metal, and causes heat exchanger fail-

ure. Addition of oxygen can cause internal corrosion in system components. Leaks

in boiler or piping must be repaired at once to prevent makeup water.

Do not add cold water to hot boiler. Thermal shock can cause boiler heat exchanger

to crack.