Wolf Appliance Company WOLF FRYER MODULE User Manual

Page 11

Advertising
background image

11

M A N UA L D R A I N

O P E R A T I O N

IMPORTANT NOTE: The fryer module must be
installed in a base cabinet that allows access to
the manual drain valve for draining the oil. A
heat-resistant bucket must be positioned under
the drain outlet to accept the oil. The bucket
must be able to hold 2 gallons (7.6 L).

To open the manual drain valve, push in the
safety latch as you turn the drain valve handle
downward. Refer to the illustration below.

W O L F

F RY E R M O D U L E

U S E & C A R E

The oil will be hot. Before opening the
drain valve, make sure that the oil has
cooled significantly—below 140˚F (60˚C)
—before draining oil into a heat-resistant
bucket. The temperature display will
continue to show oil temperature until
the oil has cooled to below 140˚F (60˚C),
even if the unit is off or in Lock mode.

Dimensions in parentheses are in
millimeters unless otherwise specified.

T I M E R

O P E R A T I O N

The control panel of the fryer module has an
independent 99-minute timer. Refer to the illus-
tration below. This function can be used with
or without the unit in operation. However, the
fryer must not be in Lock mode.

To start the timer, touch the ”+” or ”
symbol until the correct amount of time is
shown in the timer display. The timer will
begin its countdown after a two-second
delay.

A warning beep will sound when the timer
has one minute left and begins to count-
down in seconds starting at 59.

A signal will beep when time has expired
and will continue to beep every 30 seconds.

Touch CLEAR to reset the timer.

Manual drain valve

DRAIN VALVE

(closed position)

HEAT-RESISTANT BUCKET

Timer controls

Timer
display

”+” and ”–”

symbols

Advertising