MAINTENANCE

QTFSG/QTFSD 98349 05/15/03

4-3

MAIN BROOM (Refer to the Main Broom Group
and Main Broom Lift Group in the Parts section)

FOR SAFETY: The main broom and the vacuum
impeller automatically begin to operate when the
main broom lever is positioned in the forward end of
its slot.

The main broom spans the width of the machine,
and sweeps debris into the hopper. Inspect the
main broom daily for wear or damage. Remove any
obstructions found in the main broom chamber, main
broom drive hub or idler hub.

The main broom should be replaced when the
remaining bristles measure 5/8 “ (16mm) or less in
length.

NOTE: All original equipment brooms are equipped
with “Perform Alert™”. This feature tells the
operator when it is time to replace the main broom.
“Perform Alert™” brooms have bright yellow tufts
located on each end of the broom. These tufts are
pre-trimmed to indicate the length of a worn out
broom. When the main body of the broom wears to
a length that matches the yellow tufts, the broom
should be replaced.

Always check the main broom pattern when
installing a new broom.

TO REMOVE THE MAIN BROOM

1. Turn off machine and set parking brake.

FOR SAFETY: Before leaving or servicing the
machine, stop on a level surface, apply parking
brake, turn off the machine and remove key.

2. Raise rear cover.
3. Disconnect batteries from machine.
4. Lower the main broom lever.
5. Open the right side broom door.
6. Remove the idler arm D-ring retainer.
7. Remove the main broom idler arm.
8. Grasp the broom by the core and remove.

TO INSTALL THE MAIN BROOM

1. Turn off machine and set parking brake.

FOR SAFETY: Before leaving or servicing the
machine, stop on level surface, apply parking brake,
turn off machine and remove key.

2. Raise rear cover.
3. Disconnect batteries from machine.
4. Lower the main broom lever.
5. Open right side broom door.
6. If replacing a worn broom, turn the main broom

adjustment knob so that the broom drive hub is
raised to a position that will allow a new broom
to easily slide onto the broom drive hub.

7. Slide the new brush into the broom chamber.
8. Hold the broom by the core and rotate the

broom counter-clockwise while pushing the
broom onto the drive hub. Make sure that the
broom is fully seated onto the drive hub before
attempting to install the idler arm.

9. Locate the idler arm. Align the tabs on the idler

hub with the slots on the main broom core.
Slide the idler into the main broom core, the
position the upper right end of the idler arm onto
the two locator pins.

10. Replace and tighten the D-ring retainer.
11. Close the broom door.
12. Check the main broom floor pattern and adjust

as necessary.