Maintenance, Warning ! warning ! warning, Warning – Windsor TRACER FS QTFSD User Manual

Page 31

Advertising
background image

MAINTENANCE

QTFSG/QTFSD 98349 05/15/03

4-14

!

WARNING

!

WARNING

!

WARNING

SPECIFIC GRAVITY

BATTERY CONDITION

1.265

100% CHARGED

1.225

75% CHARGED

1.190

50% CHARGED

1.155

25% CHARGED

1.120

DISCHARGED

!

WARNING

BATTERY

The battery provides the power to start the machine.
The battery requires regular maintenance to keep
them operating at peak efficiency.
To get the greatest life from the battery charge it
when their charge level reaches 25%of a full charge.
Use a hydrometer to check the charge level.
Do not allow the battery to remain in a discharged
condition for any length of time. Never expose a
discharged battery to temperatures below freezing.
Discharged batteries will freeze causing cracked
case. Do not operate the machine if the battery is in
poor condition or if they have a charge level below
25%, specific gravity below 1.177.
Keep all metallic objects off the top of the battery, as
they may cause a short circuit. Replace worn or
damaged cables and terminals.
Check the electrolyte level in each battery cell
before and after charging the battery. Never add
acid to the battery, use water. Do not allow water
level to fall below the battery plates. Portions of
plates exposed to air will be destroyed. Do not
overfill. Keep plugs firmly in place at all times.
The battery in this machine is rated at 12V, 550cca.
It is located under the engine, center of frame.
When removing the battery cables, remove the
negative (-) cable before removing the positive (+)
cable.

When servicing machine, avoid contact with
acid.

Batteries emit hydrogen gas. Explosion or fire
can result. Keep sparks and open flame away.
Keep covers open when charging.

Wear eye protection and protective clothing
when working with batteries.

Charge batteries in a well-ventilated area.

BATTERY MAINTENANCE

1. When cleaning the battery, use a solution of

baking soda and water. Do not allow the
cleaning fluid to enter the battery cells.
Electrolyte will be neutralized.

2. Maintain the proper electrolyte level in each

battery cell. If a cell should accidentally
overflow, clean immediately.

3. Do not add water until the battery is fully

charged.

4. Wipe off the top of the batteries at least once a

week.

5. Test battery condition with a hydrometer at least

once a week.

6. Ensure that all connections are tight and all

corrosion removed.

7. Every 4 to 6 months, remove the batteries from

the machine and clean the battery cases and
battery compartment.

NOTE: Do not take readings immediately after
adding water. If the water and acid are not
thoroughly mixed, the reading may not be accurate.

To find the correct specific gravity reading when the
temperature of the battery electrolyte is other then
80

L F (27L C).

Add (+) to the specific gravity reading
0.004 (4 points), for each 10

L F (6L C) above 80L F

(27

L C) Subtract (-) from the specific gravity reading

0.004 (4 points), for each 10

L F (6L C) below 80L F

(27

L C).