Wall Cover Plate

50

60

70

80

90

9

12

3

6

9

1

2

3

6

DAY

90

80

70

60

50

HI

LO

Thermostat

AUTO

OFF

FAN

ON

SYSTEM

COOL

HEAT

Thermostat

Subbase*

Wall Mounting

Plate*

Junction Box

Adaptor Plate

Figure 5. Mounting 1F7X quartz clock thermostat to vertical junction box

6-32 X

3

4

” flat-head

machine screws

6-32 X

3

4

” flat-head

machine screws

*Do not use both subbase and wall

mounting plate – see note, above.

Locate and drill two

clearance holes in wall

6-32 X

3

4

” flat-head

machine screws

50

60

70

80

90

9

12

3

6

9

1

2

3

6

DAY

90

80

70

60

50

HI

LO

Thermostat

AUTO

OFF

FAN

ON

SYSTEM

COOL

HEAT

Thermostat

Subbase*

Wall Mounting

Plate*

Wall

Figure 6. Mounting 1F7X quartz clock thermostat to wall

No. 6 X 1” pan-head screws

(supplied with thermostat)

Wall Cover Plate

*Do not use both subbase and wall

mounting plate – see note, above.

No. 6 X 1” pan-head screws

(supplied with thermostat)

Do not install the wall mounting plate and subbase at the
same time. The thermostat will not operate properly if both
wall mounting plate and subbase are installed.

NOTE

Do not install the wall mounting plate and subbase at the
same time. The thermostat will not operate properly if both
wall mounting plate and subbase are installed.

NOTE

When installing wall cover plate and thermostat directly to
wall, use the pointed screws supplied with the thermostat.

NOTE