Figure 9. mounting 1f60 thermostat to wall, Thermostat (connect harness – snap onto subbase), Wall cover plate thermostat cover thermostat – White Rodgers 37-5148B User Manual

Page 6: Wall, No. 6 x, Phillips pan-head screws 6-32 x, Flat-head machine screws, Phillips pan-head screws

Advertising
background image

6

When installing wall cover plate and thermostat directly to
wall, use the pointed screws supplied with the thermostat.

Wall Cover Plate

Junction Box

Thermostat Cover

Thermostat Subbase

AM
PM

SETBACK

HEAT

COOL

Instructions Inside Cover

WHITE-RODGERS

COMPRESSOR
MALFUNCTION

EMERGENCY
HEAT

AUXILIARY
HEAT

10 50

55

60

65

70 21

75

80

85

90 32

°

F

°

C

0 3 6 9

°

C

0 5 10 15

°

F

AUTO CONT.
FAN

COOL OFF HEAT EMHT

TIME

SET

SET

BACK

CLEAR

Thermostat

(connect harness –

snap onto subbase)

Figure 10. Mounting 1F62 thermostat to horizontal junction box

No. 6 X

3

8

” Phillips

pan-head screws

6-32 X

3

4

” flat-head

machine screws

Wall Cover Plate

Thermostat Cover

Thermostat

AM
PM

SETBACK

HEAT

COOL

Instructions Inside Cover

50 60 70 80 90

°

F

10 21 32

°

C

WHITE-RODGERS

0 3 6 9

°

C

0 5 10 15

°

F

AUTO CONT.
FAN

COOL OFF HEAT

SET

BACK

TIME

SET

Wall

Figure 9. Mounting 1F60 thermostat to wall

No. 6 X 1” pan-head screws

(supplied with thermostat)

No. 6 X

3

8

” Phillips

pan-head screws

NOTE