Western Telematic IPS-400 User Manual

Page 25

Advertising
background image

5-9

Confi guration

5.3.2.

The Serial Parameters Menu

The Serial Parameters Menus are used to configure the IPS-400's serial

Console Port, and is used to select parameters such as the Baud Rate, Parity

and Modem Initialization String. To access the Serial Parameters Menu,

proceed as follows:

Web Browser Interface: Click the "Setup" button to access the Setup

Menus, and then click the "Serial Parameters" button. The Serial

Parameters Menu will be displayed as shown in Figure 5.5.

Text Interface: Type

/C and press [Enter]. The Serial Parameters

Menu will be displayed as shown in Figure 5.6.

Figure 5.5: Serial Parameters Menu - Web Browser Interface

SERIAL PARAMETERS:

1. Baud Rate: 9600

2. Data: 8 Bit

3. Parity: None

4. Stop: 1 Bit

5. Port Mode: Console

6. Modem Init. Str: ATE0M0Q1&C1&D2S0=1

Enter selection,

Press <ESC> to return to previous menu ...

Figure 5.6: Serial Parameters Menu - Text Interface