White Rodgers 1F95-1291 User Manual

Applications, Specifications, Caution

Advertising
background image

Model

Programming Choices

1F95-1291

7 Day

5/1/1 Day

Non-Programmable

www.white-rodgers.com

www.emersonclimate.com

Big Blue Humidity Universal Thermostat

with Humidity/Dehumidity Control and

Automatic Heat/Cool Changeover Option

PART NO. 37-6914E

Replaces 37-6914D

1104

Single Stage, Multi-Stage, Heat Pump

Installation and Operating Instructions

White-Rodgers is a division

of Emerson Electric Co.

www.white-rodgers.com

Printed In U.S.A.

APPLICATIONS

1F95-1291 Humidity Control Touchscreen Thermostat

SPECIFICATIONS

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.

THERMOSTAT APPLICATION GUIDE

Thermostat

Configuration Options

Thermostat

Applications

Maximum

Stages

Heat/Cool

Single Stage 1

No Heat Pump (SS1)

Gas, Oil, Electric, Heat Only,

Cool Only or Heat/Cool

Systems, 2 or 3 wire Hydronic

Zone (Hot Water or Steam)

Systems, 24 Volt or Millivolt

1/1

Multi Stage 2

No Heat Pump (MS2)

2/2

Heat Pump 1

Single Stage Compressor

Heat Pump (HP1)

Single Stage Compressor

Heat Pump Systems - up to 2

Stages Aux./Emergency Heat

3/1

Heat Pump 2

Two Stage or Two

Compressor Heat Pump

(HP2)

Two Stage or Two Compressor

Heat Pump systems - up to 2

Stages Aux./Emergency Heat

4/2

ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.

Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to

www.white-rodgers.com for location to

send the product containing mercury.

Index

Page

Installation

2

Wiring Diagrams

3

Thermostat Quick Reference

5

Installer Configuration Menu

6

Operating Your Thermostat

10

Programming

12

Troubleshooting

16

Electrical Rating:

Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC

Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5A per terminal, 2.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F
Differential (Multi-Stage) . . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F
Differential (Heat Pump) . . . . . . . . . . . . . . . . . . . . . Heat 1.2°F; Cool 1.5°F
Operating Ambient. . . . . . . . . . . . . . . . . . . . . . . . . . 32°F to +105°F (0 to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . . -40 to +150°F (-40 to +65°C)
Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . . 4-9/16"H x 5-13/16"W x 1-3/16"D

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!

Advertising