White Rodgers 1F82-0261 User Manual

Applications, Specifications, Precautions

Advertising
background image

1

Blue 2” Heat Pump Thermostat

Heat Pump Installation and Operating Instructions

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.

APPLICATIONS

1F82-0261 Thermostat

Model

Programming Choices

1F82-0261

5/1/1 Day Programmable

SPECIFICATIONS

Electrical Rating:

Battery Power or Hardwire ............................. 20 VAC, 50/60 Hz

Terminal Load ........................................................ 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ...................................................... 45° to 90°F (7° to 32°C)
Differential (Heat Pump) ........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient ................................................. 32° to +105°F (0° to +41°C)
Operating Humidity ................................................ 90% non-condensing max.
Shipping Temperature Range ................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ......................................... 3-3/4”H x 4-3/4”W x 1-1/2”D

PRECAUTIONS

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a fire hazard.

WARNING

!

PART NO. 37-7022C

Replaces 37-7022B

1023

www.white-rodgers.com

www.emersonclimate.com

Index

Page

Installation

2

Wiring Diagram

3

Thermostat Quick Reference

4

Installer Configuration Menu

5

Operation

6

Programming

7

Troubleshooting

9

THERMOSTAT APPLICATION GUIDE

Thermostat

Configuration

Options

Thermostat

Applications

Maximum

Stages

Heat/Cool

Heat Pump

Single Stage

Compressor

Single Stage Compressor

Heat Pump Systems – 1

Stage Aux/Emergency Heat

2/1

Advertising