Part Number PLUS-E017-A/1206

1

Manual

• Installation • Start-Up • Usage • Maintenance • Parts

Start-up checklist

❏

Long element T&P relief valve is properly installed and drain discharge is directed away

from all persons.

❏

Both inner and outer tanks are filled with water.

❏

All air has been bled from both domestic and boiler water systems.

❏

Automatic air vent is installed and cap is unscrewed one full turn.

❏

Cold and hot water lines are correctly connected to domestic water system.

❏

Supply and return piping from boiler is correctly connected to water heater.

❏

All wiring is installed correctly.

❏

Thermostat on water heater is set according to system requirements. See pages 18–19.

❏

Boiler and water heater are operating properly.

❏

Fittings and piping have been checked for leaks.

❏

Installer has reviewed the following sections with system maintainer:

• Water Heater Start-Up

• Adjusting Water Heater Temperature

• Water Heater Maintenance

Water heater start-up

continued