Environmental Requirements
The DocuColor 8000/7000 will enter the Power Saver mode after
15 minutes of no activity on the machine.
The factory default time of 15 minutes can be changed in the Tools
Mode.
Ambient Temperature and Humidity
10 to 32°C, 15 to 85% RH
50 to 90°F, 15 to 85% RH
NOTE: Above 82°F (28°C), reduced humidity is required to
maintain the specified performance.
Altitude
Normal operation: 0 to 2,500 meters (0 to 8,200 feet).
Operation between 2,000 to 2,500 meters (6,557 to 8,200 feet)
may require a field adjustment.
Illumination
Normal function (free from print quality defects) can be expected
under 3,000 lx maximum.