6. Maintenance
2. Clean each corotron by
slowly
pulling out and pushing in the
Cleaning Wand one time.
KEY POINT:
To ensure proper cleaning of the pad,
slowly
pull out
the wand
until it reaches the end of the assembly
;
it will stop
when it reaches the end
. Slowly push in the wand until it is fully
seated against the corotron assembly.
CAUTION:
To avoid damage to the corotron assembly,
carefully
and
slowly
pull out the Cleaning Wand. Once the wand reaches
the end of the assembly, it stops. Do not continue to pull on the
wand as this will remove the wand from the Corotron Assembly,
thereby damaging the assembly. If this occurs, you must replace
the entire Corotron Assembly.
Slowly
pull out the wand,
then push it back in