Menu 11.1 - Remote Node Profile

Rem Node Name= ChangeMe Route= IP
Active= Yes ISP= No
Apply Alias= None
Encapsulation= Ethernet Edit IP= No
Service Type= Standard Session Options:
Service Name= N/A Edit Filter Sets= No
Outgoing:
My Login= N/A
My Password= N/A
Retype to Confirm= N/A
Server= N/A
Relogin Every (min)= N/A

Press ENTER to Confirm or ESC to Cancel:
Press ENTER to Confirm or ESC to Cancel:

Menu 11.1 Remote Node Profile for Ethernet Encapsulation

The following table describes the fields in this menu.

Table 95 Menu 11.1 Remote Node Profile for Ethernet Encapsulation

FIELD

DESCRIPTION

Rem Node Name

Enter a descriptive name for the remote node. This field can be up to eight

characters.

Active

Press [SPACE BAR] and then [ENTER] to select Yes (activate remote node) or

No (deactivate remote node).

Encapsulation

Ethernet is the default encapsulation. Press [SPACE BAR] and then [ENTER] to

change to PPPoE or PPTP encapsulation.

Service Type

Press [SPACE BAR] and then [ENTER] to select from Standard, RR-Toshiba

(RoadRunner Toshiba authentication method), RR-Manager (RoadRunner

Manager authentication method), RR-Telstra or Telia Login. Choose one of the

RoadRunner methods if your ISP is Time Warner's RoadRunner; otherwise

choose Standard.

Outgoing

My Login

This field is applicable for PPPoE encapsulation only. Enter the login name

assigned by your ISP when the ZyAIR calls this remote node. Some ISPs append

this field to the Service Name field above (e.g., jim@poellc) to access the PPPoE

server.

My Password

Enter the password assigned by your ISP when the ZyAIR calls this remote node.

Valid for PPPoE encapsulation only.

Retype to Confirm

Type your password again to make sure that you have entered it correctly.

Server

This field is valid only when RoadRunner is selected in the Service Type field.

The ZyAIR will find the RoadRunner Server IP automatically if this field is left

blank. If it does not, then you must enter the authentication server IP address

here.

Relogin Every

(min)

This field is available when you select Telia Login in the Service Type field.
The Telia server logs the ZyAIR out if the ZyAIR does not log in periodically. Type

the number of minutes from 1 to 59 (30 recommended) for the ZyAIR to wait

between logins.