Status Registers and Result Codes 129
Command bit dec hex Function and description
Ref.
64
40
Profile 2 as active settings after
power ON.
Z2
96
60
Profile 3 as active settings after
power on.
Z3
128 80 * Factory default as active
settings after power ON.
Z4
S16=
dec hex Test status register.
+000
0
0
No test in progress.
&T0
S18=
dec
Force modem or TA to fix baud
rate when idle.
+000
0 *
Disable fixed baud function
n+1
Enable baud rate fixing at idle,
n=0-15 baud rate value settings
(n) the same as S20 value.
S20=
dec hex DTE speed (bps). Auto
detected from AT Command.
+003
0
0
230400 bps
1
1
115200 bps
3
3
57600 bps
4
4
38400 bps
5
5
19200 bps
9
9
9600 bps
11
B
4800 bps
12
C
2400 bps
13
D
1200 bps
14
E
460800 bps
15
F
921600 bps
S21=
bit dec hex Bit mapped register.
1-2 0
0
Speaker always Off.
M0
2
2
Speaker On until carrier is
detected.
M1
4
4
Speaker always On.
M2
3
0
0
DSR always On.
&S0