3.0 OPERATION

14

©2002 Xantrex Technology Inc.

P/N 973-0022-01-01 Rev A 04/2002

Starting the Program

From Windows:

1. Open

MY COMPUTER or WINDOWS EXPLORER.

2. Locate the file

“swcps.exe” and double-click it.

or

1. Click

START.

2. Select

RUN.

3. Type

“swcps” and press <Enter>.

From DOS (or a DOS prompt within Windows):

1. Locate the file

“swcps.exe”.

2. Type

“swcps” and press <Enter>.

When the program starts, a line drawing of the SW series control panel will

appear on the computer screen. You can resize the MSDOS window for better
viewing of the control panel if the labeling is not clear.

ID Numbers

Once the program has started, it looks for an SWCA programmed with an

ID number of “1”. This is the default ID number of all adapters. If two adapters
are connected to a PC with the same ID number, you will not be able to
communicate with either until the adapters have different ID numbers.

Refer to Table 3-1 on page 11 for information on accessing the SWCA
Programming Menu to reprogram the adapters with a different ID number.

The program also assumes that the SWCA is connected to a serial port with

a COM number of 1. If you are using a COM port other than one, refer to the
paragraph in this section titled

Changing the PC’s COM Port Number.

Changing the PC’s COM Port Number

To change the COM port number that the control panel simulator DOS

program uses to find the adapter, add the COM port ID number (1-4) after the
DOS command used to start the SWCPS program as follows:

C:> SWCPS 2

This command causes the program to look at the COM 2 port on the PC for

the SWCA adapters.