Figure 3 - unit dimensions keu180, Table 20: unit clearances keu180, Accessories – York EVAPORATOR BLOWERS K2EU060 User Manual

Page 18

Advertising
background image

036-21300-002-A-0905

18

Unitary Products Group

ACCESSORIES

ELECTRIC HEATER - Add 14-1/4” to unit height when using 10,
16, 26, or 36 KW heater

SUPPLY AIR PLENUM - Add 27” to unit height when used.

BASE - Add 24” to unit height when used.

HOT WATER OR STEAM COIL - Add 6” to unit depth when used.

FIGURE 3 - UNIT DIMENSIONS KEU180

2 7 - 5 / 8

2 - 3 / 8

2 - 3 / 1 6

5 6 - 3 / 8

1

2 - 3 / 1 6

3 1 - 5 / 8

3 - 1 / 8

6 2 - 5 / 8

1 - 1 / 4 " K N O C K O U T

F O R 7 / 8 " O D D R A I N

C O N N E C T I O N *

( M u s t b e t r a p p e d )

F I L T E R A C C E S S P A N E L

F i l t e r s c a n b e r e m o v e d

t h r o u g h e i t h e r s i d e o f

t h e u n i t .

1 - 1 / 4 " K N O C K O U T F O R

5 / 8 " O D L I Q U I D C O N N E C T I O N *

C O I L

S E C T .

6 - 1 / 4

3 - 1 / 8

3 - 1 / 8

1 9

1 0

2 - 1 / 8

2 - 5 / 8 "

K N O C K -

O U T F O R

1 - 5 / 8 " O D

S U C T I O N

C O N N . *

3 2 - 3 / 8

1 8 - 7 / 8

6

5 - 1 / 2

5 - 7 / 8

B L O W E R

S E C T I O N

7 - 1 / 4

1 6 - 1 / 2

7 / 8

1 9 - 3 / 8

2 1 - 7 / 8

6 0 - 3 / 4

B L O W E R M O T O R A N D D R I V E A C C E S S P A N E L

( A l w a y s o n t h e w i r i n g c o n n e c t i o n s i d e o f u n i t )

L o c a t e d o n o p p o s i t e s i d e O N L Y w h e n t h e b l o w e r

s e c t i o n h a s b e e n r o t a t e d 1 8 0 f r o m p o s i t i o n s h o w n .

1 - 2 3 / 3 2 " K N O C K O U T

R e m o v e o n l y w h e n E l e c t r i c

H e a t A c c e s s o r y i s u s e d .

7 / 8 " K N O C K O U T F O R P O W E R W I R I N G

D o n o t r e m o v e t h i s k n o c k o u t w h e n t h e u n i t i s e q u i p p e d w i t h a n E l e c t r i c

H e a t A c c e s s o r y . R e f e r t o d e t a i l o f t h e H e a t e r A c c e s s o r y f o r p o w e r

w i r i n g a c c e s s o p e n i n g

7 / 8 " K N O C K O U T F O R

C O N T R O L W I R I N G

A L T E R N A T E

2 - 5 / 8 " K N O C K O U T *

* R e f e r t o I N S T A L L I N G R E F R I G E R A N T M A I N S i n i n s t a l l a t i o n i n s t r u c t i o n

w h e n p i p i n g t h r o u g h t h e o p p o s i t e s i d e o f t h e u n i t .

A I R

O U T

A I R

I N

TABLE 20: UNIT CLEARANCES KEU180

MINIMUM CLEARANCES

180

Side Air with RETURN AIR opening

24”

Side with SUPPLY AIR opening

1

24”

Side with PIPING CONNECTIONS

2

61”

Side opposite PIPING CONNECTIONS

3

26”

Bottom

4

-

1. Overall dimension of the unit will vary if an electric

heater, a supply air plenum or a base is used.

2. This dimension is required for removal of the DX coil.

Only 26” is required for normal servicing.

3. If the coil has to be removed, this dimension is required

to loosen screws that secure the coil to the unit frame.
This dimension will also be required for blower motor
access if the piping connections are made on the oppo-
site side of the unit.

4. Allow enough clearance to trap the condensate drain

lines.

All dimensions are in inches. They are
subject to change without notice. Certi-
fied dimensions will be provided upon
request.