Figure 10 - field wiring for power supply, Figure 11 - cooling only unit, Units with electric heat accessory – York EVAPORATOR BLOWERS K2EU060 User Manual

Page 24

Advertising
background image

036-21300-002-A-0905

24

Unitary Products Group

FIGURE 10 - FIELD WIRING FOR POWER SUPPLY

COOLING ONLY UNITS AND UNITS WITH

STEAM OR HOT WATER COIL ACCESSORY

TERMINALS ON

SUPPLY AIR

BLOWER MOTOR

CONTACTOR 10M

GROUND

SCREW

POWER WIRING,

DESCONNECT SWITCH

AND FUSING TO BE

SUPPLIED BY FIELD

LINE VOLTAGE

POWER SUPPLY

*Not required on 060 (1-Phase

only) All other units are 3-Phase.

TERMINALS

ON FUSE HOLDER

IN ELECTRIC HEAR

CONTROL BOX

GROUND LUG

IN ELECTRIC HEAT

CONTROL BOX

POWER WIRING,

DESCONNECT

SWITCH

AND FUSING

(OR CIRCUIT

BREAKER)

TO BE SUPPLIED

BY FIELD

3-PHASE

LINE VOLTAGE

POWER SUPPLY

NOTE: USE COPPER

CONDUCTORS ONLY

WIRE IN ACCORDANCE WITH LOCAL

AND NATIONAL ELECTRICAL CODES

UNITS WITH ELECTRIC HEAT ACCESSORY

FIGURE 11 - COOLING ONLY UNIT

TERMINALS ON

THERMOSTAT 6TH13700724

WITH SUB-BASE 2TB08700124

TERMINAL

BLOCK 4TB

ON BLOWER UNIT

1-STAGE COOLING

24-VOLT

CONTROL

WIRING

TO

COND.

UNIT

R

R

Y

Y

G

G

B

TERMINALS ON

THERMOSTAT 6TH04701724

WITH SUB-BASE 2TB04700124

24-VOLT

CONTROL

WIRING

TERMINAL BLOCK 4TB

ON BLOWER UNIT

TO

COND.

UNIT

2-STAGE COOLING FOR HCA180/KEU180**

COOLING ONLY UNITS

RC

Y1

Y2

G

R

Y

O

G

B

FIGURE 12 - UNIT WITH STEAM OR HOT WATER COIL ACCESSORY

24-VOLT CONTROL WIRING

TO

COND.

UNIT

TERMINAL

BLOCK 4TB

ON BLOWER UNIT

TO HEATER COIL

CONTROL CIRCUIT

TERMINALS ON

THERMOSTAT

6TH04701524

WITH SUB-BASE

2TB04700324

TERMINAL

BLOCK 4TB

ON BLOWER UNIT

TO HEATER COIL

CONTROL CIRCUIT

TERMINALS ON THERMOSTAT 6TH13700724

WITH SUB-BASE 2TB17700324

24-VOLT CONTROL WIRING

1-STAGE COOLING

2-STAGE COOLING FOR HCA180/KEU180**

UNITS WITH STEAM OR HOT WATER COIL ACCESSORY

R

Y

G

W

R

Y

G

B

R

Y1

Y2

G

W

R

Y

O

G

B

TO

COND.

UNIT

Advertising
This manual is related to the following products: