Xantrex Technology XDC 20-600 User Manual

Page 186

Advertising
background image

Remote Operation

4–72

TM-XDOP-01XN

Temperature Sub-Register Commands

Query Questionable Temperature Sub-Register Event

Temperature Event Sub-Register is read and then cleared.

SCPI command:

STATus[<channel>]:QUEStionable:TEMPerature[:EVENt]?

Query Questionable Temperature Sub-Register Condition

SCPI command:

STATus[<channel>]:QUEStionable:TEMPerature:CONDition?

Enable Temperature Sub-Register

SCPI command:

STATus[<channel>]:QUEStionable:TEMPerature:ENABle <status-

enable>

Query Format:

STATus[<channel>]:QUEStionable:TEMPerature:ENABle?

Set Temperature Positive Transition Filter

SCPI command:

STATus[<channel>]:QUEStionable:TEMPerature:PTRansition

<status-enable>

Query Format:

STATus[<channel>]:QUEStionable:TEMPerature:PTRansition?

Set Temperature Negative Transition Filter

SCPI command:

STATus[<channel>]:QUEStionable:TEMPerature:NTRansition

<status-enable>

Query Format:

STATus[<channel>]:QUEStionable:TEMPerature:NTRansition?

TM-XDOP-01XN.book Page 72 Monday, July 17, 2006 11:19 AM