Xantrex Technology XDC 20-600 User Manual
Page 249

S
C
PI C
o
mmand S
u
mmary
TM-XDOP-01XN
C
–25
Set Questionable
Status Power
Negative Transition
Register
[:]STATus[<channel>]:QUEStionable:POWer:NTRans
ition <status-enable>
See Table 4-18 on page 4–53.
Yes
Set Questionable
Status Power
Positive Transition
Register
[:]STATus[<channel>]:QUEStionable:POWer:PTRans
ition <status-enable>
See Table 4-18 on page 4–53.
Yes
Query Questionable
Status Temperature
Condition Register
[:]STATus[<channel>]:QUEStionable:TEMPerature:
CONDition?
See Table 4-19 on page 4–54
N/A
Set Questionable
Status Temperature
Enable Register
[:]STATus[<channel>]:QUEStionable:TEMPerature:
ENABle <status-enable>
See Table 4-19 on page 4–54.
Yes
Query Questionable
Status Temperature
Event Register
[:]STATus[<channel>]:QUEStionable:TEMPerature[
:EVENt]?
See Table 4-19 on page 4–54
N/A
Set Questionable
Status Temperature
Negative Transition
Register
[:]STATus[<channel>]:QUEStionable:TEMPerature:
NTRansition <status-enable>
See Table 4-19 on page 4–54
Yes
Set Questionable
Status Temperature
Positive Transition
Register
[:]STATus[<channel>]:QUEStionable:TEMPerature:
PTRansition <status-enable>
See Table 4-19 on page 4–54
Yes
Query Questionable
Status Voltage
Condition Register
[:]STATus[<channel>]:QUEStionable:VOLTage:COND
ition?
See Table 4-16 on page 4–53.
N/A
Set Questionable
Status Voltage
Enable Register
[:]STATus[<channel>]:QUEStionable:VOLTage:ENAB
le <status-enable>
See Table 4-16 on page 4–53.
Yes
Table C-10 Status Commands
Function
SCPI Command
Description
Query