Power Switch

The Power Switch is located on the

front panel. This switch controls ON/OFF
and RESET for the inverter. Expect a 3
second delay when the power switch is
turned ON before the unit is activated.

If the unit is connected to external AC

power, the battery charger and transfer
switch will continue to function, regardless
of the position of the switch.

When external AC power is removed

and the power switch is in the ON position,
the inverter will automatically be ON. If the
switch is in the OFF position and external
AC power is removed, the inverter will be
OFF.

Inverter overload protection, transfer

switching, power sharing and battery
charger regulation will all function automati-
cally.

If installed with the remote control

panel, the power switch on the unit should
be left in the OFF position. Refer to Re-
mote Control Panel, page 7.