Remote control panel – Xantrex Technology 2500 User Manual

Page 8

Advertising
background image

90-0115-00
10/97 Fltman.pm65

REMOTE CONTROL PANEL

Dip Switches

On the back of the Fleet Power remote

control panel is a set of 8 dip switches
which are used to make several adjust-
ments. On the switch block, each switch is
numbered . . .1 through 8 and the ON posi-
tion is indicated. The switch settings can be
changed at any time, even while the unit is
operating. Following is a discussion of
each adjustment. Refer to the table on
page 11 for dip switch programming.

SWITCH 1 -

Manual Equalizing

Cy-

cling this switch ON for 1 second, then OFF,
will initiate an equalizing charge cycle. The
battery charger must be engaged before
cycling the switch. The dip switch must
always be returned to the OFF position.
If it is left ON, an equalizing charge cycle
will initiate every time the charger is
engaged - this could cause battery dam-
age.

The equalizing cycle is timed to last 8

hours from the time the switch is cycled, at
which point the charger resumes normal
charging in the float stage.

The battery LED blinks when equaliz-

ing. See page 18 for a discussion of the
theory and procedure for battery equalizing.

SWITCH #2 & #3 -

Battery Type

Gel cell

and wet cell batteries have slightly different
charge voltage requirements. Optimum
battery charging is temperature dependent.
For these reasons, the dip switches allow
four different battery charger voltage set
points, depending on battery type and
ambient temperature:

Cool Wet Cell

< 80 degrees F.

Warm Wet Cell

> 80 degrees F.

Cool Gel Cell

< 80 degrees F.

Warm Gel Cell

> 80 degrees F.

Refer to the table on page 21 for the

specific voltages for each setting.

SWITCH #4 -

Auto Charge

With the switch

in the OFF position, the remote panel ON/
OFF switch only controls the inverter opera-
tion. With the switch turned ON, it allows
the power ON/OFF switch on the front of the
remote to control the battery charger as well
as the inverter.

SWITCH #5 & #6 - Not used for adjust-
ments.

SWITCH #7 & #8 -

Power Sharing

These

switches should be set to match the value of
the circuit breaker which protects the incom-
ing AC power. They may also limit the
output current from the battery charger.

8

BACK VIEW

Fleet Power Remote Control Panel

Advertising