Chapter 4 Powerline Network Setup Tutorial

PLA-4xx Series User’s Guide

39

Figure 27 Local/Remote Adapters on a Powerline Network

3 To set up a new powerline network, type the DAK Password and change the Network

Password (NMK) on all powerline adapters you wish to add to your network.

• Look for the DAK Password on a label on your powerline adapter. The DAK

Password lets you access the adapter.

• Select the Remote adapter you want to add (A) and type the DAK Password in

the DAK Password field (B).

• Then type the new network password in the Network Password (NMK) field.

Figure 28 Adding an Adapter to Your New Network

4 Click Save.

• If you do not type the DAK password or type it incorrectly either of the following pop-

ups appears. Click OK and type the DAK Password correctly in the DAK Password
field.