ZyXEL Communications Prestige 314 PLUS User Manual

Page 79

Advertising
background image

Prestige 314 PLUS Broadband Sharing Gateway with 4-Port Switch

NAT

4-17

4. The Prestige forwards the traffic to Jane’s computer IP address.

5. Only Jane can connect to the Real Audio server until the connection is closed or times out. The

Prestige times out in three minutes with UDP (User Datagram Protocol) or two hours with TCP/IP
(Transfer Control Protocol/Internet Protocol).

Two Points To Remember About Trigger Ports

1. Trigger events only happen on data that is going coming from inside the Prestige and going to the

outside.

2. If an application needs a continuous data stream, that port (range) will be tied up so that another

computer on the LAN can’t trigger it.

Only one LAN computer can use a trigger port (range) at a time.

Enter 3 in menu 15 to display Menu 15.3 — Trigger Port Setup, shown next.

Figure 4-13 Menu 15.3: Trigger Port Setup

Menu 15.3 - Trigger Port Setup

Incoming

Trigger

Rule

Name

Start Port End Port Start Port End Port

----------------------------------------------------------------------

1.

Real Audio

6970

7170

7070

7070

2.

0

0

0

0

3.

0

0

0

0

4.

0

0

0

0

5.

0

0

0

0

6.

0

0

0

0

7.

0

0

0

0

8.

0

0

0

0

9.

0

0

0

0

10.

0

0

0

0

11.

0

0

0

0

12.

0

0

0

0

Press ENTER to Confirm or ESC to Cancel: