Calculating External Battery Charging Time

975-0343-01-01

B-3

Calculating External Battery Charging Time

Formula

Charging time will depend on the capacity of your battery
and on how deeply it is discharged.The following equation
calculates an approximate charging time:

where:

Example

A Group 27 size battery rated at 82 amp-hours is 40%
discharged, that is, it has a DOD = 40. Charging time with a
Duracell® Charger unit is calculated as follows:

Charging Time:

Battery recharge time in hours

CAP:

Battery capacity in amp-hours

DOD:

Battery depth of discharge in per cent. A fully
discharged battery has 100% DOD

CC:

Charge current, the rated current output of the
charger in amperes

80%:

Typical charging efficiency for lead-acid batteries

Charging time = CAP x DOD

CC x 80%

Charging time = 82 Ah x 40% = 2 hours

20 A x 80%