Battery Reconditioning Mode

975-0343-01-01

B-5

About Reconditioning

Frequency

Approximately once a month, you may wish to recondition
your flooded batteries by using the battery reconditioning
mode.

Important

Reconditioning can damage your batteries if it is not
performed properly. Never recondition a battery more than
twice a month. Always check battery fluid level before and
after reconditioning. Fill batteries only with distilled water.

Battery manufacturers' recommendations on reconditioning
vary. Always follow the battery manufacturer's instructions
so batteries are properly reconditioned. As a guide, a heavily
used battery may require reconditioning once a month while a
battery in light duty service, only needs reconditioning every
two to four months. Duracell® Charger provides a high-
quality charge so batteries will not need to be reconditioned
as often as with a lower quality charger.

Battery type

Duracell® Charger reconditions only flooded lead-acid
batteries. It does not recondition sealed lead-acid batteries
since they can be damaged by this process.

Duration

Reconditioning is manually terminated when the specific
gravity in each cell is about 1.265 and remains constant at
that level. Duracell® Charger automatically exits the
reconditioning mode after six hours.

Battery charge state

Reconditioning is only performed on fully-charged batteries.
If they are not charged, the first part of the process is similar
to the absorption charge and ensures the battery is fully
charged.

Recommended

The manufacturer recommends that you run a normal charge
cycle on the batteries before you recondition them.