Following Safety Information

Before installing or removing any components from
the Switch, or carrying out any maintenance proce-
dures, you must read the safety information pro-
vided in

Appendix A

of this guide.

Positioning the Switch 1000

The Switch is suited for use in the office where it
can be wall-mounted, mounted in a standard
19-inch equipment rack, or free standing. Alterna-
tively, the unit can be rack-mounted in a wiring
closet or equipment room. A wall-mounting /
rack-mounting kit, containing two mounting brack-
ets and six screws, is supplied with the Switch.

When deciding where to position the unit, ensure
that:

You are able to meet the configuration rules
detailed in the following section.

The unit is accessible and cables can be con-
nected easily.

Cabling is away from:

Sources of electrical noise such as radios,
transmitters and broadband amplifiers.

Power lines and fluorescent lighting fixtures.

Water or moisture cannot enter the case of the
unit.

Air-flow around the unit and through the vents in
the side of the case is not restricted. We recom-
mend that you provide a minimum 25mm (1in.)
clearance.

No objects are placed on top of the unit.

Units are not stacked more than four high if
free-standing.