*MODAL PRINT
13.14
*MODAL PRINT:
Print generalized coordinate (modal amplitude) data during a mode-
based dynamic procedure.
This option is used during mode-based dynamic procedures to control the printed output of generalized
coordinate (modal amplitude and phase) values.
Product:
ABAQUS/Standard
Type:
History data
Level:
Step
Reference:
•
“Output to the data and results files,” Section 4.1.2 of the ABAQUS Analysis User’s Manual
Optional parameter:
FREQUENCY
Set this parameter equal to the output frequency, in increments. The output will always be printed
at the last increment of each step unless FREQUENCY=0. The default is FREQUENCY=1. Set
FREQUENCY=0 to suppress the output.
Data lines to request modal output in the data file:
First line:
1. Give the identifying keys for the variables to be printed. The keys are defined in the “Modal
variables” section of “ABAQUS/Standard output variable identifiers,” Section 4.2.1 of the
ABAQUS Analysis User’s Manual.
Repeat this data line as often as necessary: each line defines a table.