*SURFACE INTERACTION

18.49

*SURFACE INTERACTION:

Define surface interaction properties.

This option is used to create a surface interaction property definition. The surface interaction properties will
govern any contact interactions that reference this surface interaction.

Products:

ABAQUS/Standard

ABAQUS/Explicit

Type:

Model data in ABAQUS/Standard; Model or history data in ABAQUS/Explicit

Level:

Model in ABAQUS/Standard, Model or Step in ABAQUS/Explicit

References:

•

“Surface properties for ABAQUS/Explicit contact pairs,” Section 29.4.2 of the ABAQUS Analysis
User’s Manual

•

“Mechanical contact properties: overview,” Section 30.1.1 of the ABAQUS Analysis User’s Manual

•

“Contact pressure-overclosure relationships,” Section 30.1.2 of the ABAQUS Analysis User’s Manual

•

“Contact damping,” Section 30.1.3 of the ABAQUS Analysis User’s Manual

•

“Frictional behavior,” Section 30.1.5 of the ABAQUS Analysis User’s Manual

•

“User-defined interfacial constitutive behavior,” Section 30.1.6 of the ABAQUS Analysis User’s Manual

•

“Breakable bonds,” Section 30.1.9 of the ABAQUS Analysis User’s Manual

•

“Thermal contact properties,” Section 30.2.1 of the ABAQUS Analysis User’s Manual

•

“Electrical contact properties,” Section 30.3.1 of the ABAQUS Analysis User’s Manual

•

“Pore fluid contact properties,” Section 30.4.1 of the ABAQUS Analysis User’s Manual

Required parameter:

NAME

Set this parameter equal to a label that will be used to refer to this surface interaction property.

Use this label on the INTERACTION parameter of the *CONTACT PAIR option (for an

ABAQUS/Standard contact analysis or an ABAQUS/Explicit analysis using the contact pair
algorithm) or on the data line of the *CONTACT PROPERTY ASSIGNMENT option (for an
ABAQUS/Explicit analysis using the general contact algorithm) to assign this surface interaction
property to a contact interaction.

Optional parameters:

PAD THICKNESS

This parameter applies only to ABAQUS/Explicit analyses using the contact pair algorithm.

18.49–1