GE SECURITY Concord User Manual

Page 45

Advertising
background image

Concord

37

3.

Disarm to Level 1 to exit Test Mode.

Phone Communication Test

The purpose of this weekly test is to verify that the connection between the central monitoring
station and your system are working properly.

Most phone tests take only a few minutes, however, your system will try for up to 15 minutes to
establish a connection.

To perform a phone communication test:

1. Disarm the system.

2. Press

8

+ System or Partition Master

CODE

+

2

.

touchpads display, “]PHONE TEST” or “System Armed to PHONE TEST.”

3. If the phone test is successful:

the optional voice module will announce, “Phone Test OK.”

Within a few minutes, the display should return to the Level 1 display. If it does not return in
three minutes, note how long before the Level 1 display returns and contact the installer.

After the test has started, the arming level can be changed to 1—Off, then to 2—Stay or 3—
AWAY, if you wish.

Keychain Touchpad

Press and hold the Lock

and Unlock

buttons

simultaneously for 3 seconds.

Zones nn OK

TOUCHPAD nn OK

Press and hold the Star

and Light

buttons

simultaneously for 3 seconds.

Touchpad Panic AUXILIARY OK

AUXILIARY PANIC OK

Panic button

Press and hold the appropriate panic button(s) for 3
full seconds.

Zones nn OK

SENSOR nn OK

Door/window sensor

Open the secured door or window.

Zones nn OK

SENSOR nn OK

Smoke detector

Press and hold the test button until the system sounds
transmission beeps.

Zones nn OK

SENSOR nn OK

Motion detector

Avoid the motion detector view for 5 minutes, then
enter its view.

Zones nn OK

SENSOR nn OK

Rate-of-Rise Heat Detec-
tor (Not UL investigated)

Rub your hands together until warm, then place one
hand on the detector for 30 seconds.

Zones nn OK

SENSOR nn OK

Shock sensor
(Not UL investigated)

Tap the glass twice, away from the sensor. Wait at
least 30 seconds before testing again.

Zones nn OK

SENSOR nn OK

Phone Interface and
Voice Module

Activate a Police panic by accessing the system using
the phone and pressing

*

+

*

+

*

+

*

+

*

+

*

.

POLICE PANIC OK

Supervised wireless siren Unplug the siren and check the touchpad display.

Plug the siren in.

SENSOR nn OK

Zones nn OK

Glass guard sensor
(Not UL investigated)

Tap the glass 3 or 4 inches from the sensor.

Zones nn OK

SENSOR nn OK

Freeze sensor
(Not UL investigated)

Apply an ice cube wrapped in plastic to the sensor. Do
not allow the sensor to get wet.

Zones nn OK

SENSOR nn OK

If you need more time to complete testing, restart the timer by pressing

8

+

CODE

+

3

.

Check to see that all sensors have been tested by pressing

*

. Touchpads display a list of untested sensors.

You will know that you have finished testing when touchpads display, “SENSOR TEST OK” or “ZONES ALL
TESTED.”

Device

Test Procedure

Touchpad Result(s)

Advertising