Upgrading software using the boot menu, Upgrading software using the boot menu 52 – 3Com 3C16895 User Manual

Page 52

Advertising
background image

52

C

HAPTER

4: M

AINTAINING

S

OFTWARE

Trying ...

Press CTRL+K to abort

Connected.

220 3Com 3CDaemon FTP Server Version 2.0

User(none):anonymous

331 User name ok, need password

Password: xxxxxxx

230 User logged in

[ftp]bin

200 Type set to I.

[ftp]get sw7750003.app

200 PORT command successful.

150 File status OK ; about to open data connection

226 Closing data connection; File transfer successful.

FTP: 3794803 byte(s) received in 130.480 second(s)

29.08Kbyte(s)/sec.

[ftp]quit

221 Service closing control connection

<SW7750>boot boot-loader primary sw7750003.app

The specified file will be booted next time!

<SW7750>reboot

This will reboot Switch. Continue? [Y/N] y

For more detailed descriptions of the setup and procedures for upgrading
software, see the remaining sections in this chapter.

Upgrading Software

Using The BOOT Menu

To perform this procedure, you must have a network connection to the
management port on the Switch 7750 Fabric module.

After powering on the Switch 7750, the BootROM program runs automatically.
The terminal displays the following information:

Starting......

RAMLine.....OK

System is booting.....................

******************************************

* *

* Switch 7750 BOOTROM, Version 500 *

* *

******************************************

Copyright (c) : 2003-2005 3Com Corporation

Creation date : Jan 20 2005, 09:37:12

CPU type : MPC8245

CPU Clock Speed : 400Mhz

BUS Clock Speed : 66Mhz

BOOT_FLASH type : M29W040B

Flash Size : 32MB

Memory Size : 256MB