Calibrate Raw

Syntax:

<SOH>CR<CR>

Description:

Allows the collection of raw (signed) X and Y coordinates before the normal scaling,
linearization, and filtering processes. The controller sends a continuous stream of data in
Calibrate Raw mode.

The Calibrate Raw data is a 5-byte packet that includes 1 status byte and 4 bytes of
binary X/Y coordinate data. Each X/Y coordinate includes 10 binary bits and 1 sign bit.
The 10 bits represent coordinates within a range of -1024 to +1023.

To use the Calibrate Raw command, the controller and host system must be in an 8-bit
data communication mode. The Calibrate Raw command returns a negative response if
the controller is not using an 8-bit communication mode. To end Calibrate Raw mode,
issue a Reset command.

3M Touch Systems uses the Calibrate Raw command during manufacturing and testing,
and recommends you only use this command for diagnostics when you want raw data.

Response:

<SOH>0<CR> Positive response.

After the controller is in Calibrate Raw mode, the controller returns a response in the
following format:

SXxYy where:

S =

Status byte, first byte of data. Refer to Error! Reference source
not found.
6.

Xx = X (horizontal) coordinate data; second and third bytes of data
Yy = Y (vertical) coordinate data; fourth and fifth bytes of data.

Table 6 Data Sequence

MSB*

Bits

LSB*

Data Sequence 7

6

5

4

3

2

1

0

S- Byte 1

1

S6

Reserved

X- Byte 2

0

X3

X2

X1

X0

Reserved

x-

Byte

3

0 Xs**

X9 X8 X7 X6 X5 X4

Y- Byte 4

0

Y3

Y2

Y1

Y0

Reserved

y-

Byte

5

0 Ys**

Y9 Y8 Y7 Y6 Y5 Y4

*MSB = Most Significant Bit, LSB = Least Significant Bit
** s = sign bit