3M™ MicroTouch™ Controller SX112 Reference Guide

33

3M Touch Systems, Inc. Proprietary Information

±8 kV Contact Discharge

*

- 1 “touch” allowed

Compliant with Class 2 operation per section 9 of IEC 61000-4-2

±22 kV Air Discharge

*

– Normal Operation – No false touches

Compliant with Class 1 operation per section 9 of IEC 61000-4-2

* ESD discharges to the tip and tapered end of the pen when connected to an SX112 controller

Operating and Storage Environmental Conditions

Operating Temperature Range

- 15

°C to +70 °C

Operating Humidity Range

< 36° C 0-90% RH

(All Humidity is Non-Condensing)

≥ 36

°C see Figure below

Storage Temperature Range

- 30

°C to +70 °C

Storage Humidity Range

< 36°C 0-90% RH

(All Humidity is Non-Condensing)

≥ 36

°C see Figure below

Agency Compliance

UL Recognized Component (UL File No. E155649)

Reliability – Mean Time To Failure

4 Million Hours MTTF -

Calculated per Mil Handbook 217-F1 @ 35°C

Storage and Operating Temperature with Humidity Conditions