3M™ MicroTouch™ Controller SX112 Reference Guide

3M Touch Systems, Inc. Proprietary Information

Mode Stream

Syntax:

<SOH>MS<CR>

Description:

Sends a continuous stream of X/Y coordinate data when you touch the sensor. The
controller continues to send data as long as you touch the sensor. The controller sends the
data even if the touch is stationary and unchanging.

The format of the coordinate data depends on the last format command received by the
controller.

Response:

<SOH>0<CR> Positive response.

Name Command

Syntax:

<SOH>NM<CR>

Description:

This

command returns a string of characters to help identify the controller. The

string contains the controller model number and current firmware revision
number. The content and format of this command can change and therefore is not
intended for normal customer use.

Null Command

Syntax: <SOH>Z<CR>

Description:

Queries the controller and waits for a response.

Use Z to determine that you are communicating with the controller or to make sure that a
utility is communicating with the controller. Using this command does not affect the
controller’s current operating parameters.

Response: <SOH>0<CR> Positive response.

Output Identity

Syntax:

<SOH>OI<CR>

Description:

Returns a 6-character random identifier, which describes the controller type and the
firmware version number.

Response:

<SOH>CcXxxx<CR>

where:

Cc

= Two ASCII characters that describe the type of 3M™ MicroTouch™

controller.

Xxxx = Four ASCII characters that indicate a build identifier.